FC Rau FC OM5 Duplex Patch Cord

FC Rau FC OM5 Duplex Patch Cord

OPTICO FC rau FC thaj qaum qaum optic fiber ntau cable yog tsim rau ceev Ethernet, gigabit Ethernet thiab fiber ntau channel daim ntaub ntawv, xws li nyob rau hauv cov ntaub ntawv chaw, telecom chav, neeg rau zaub mov ua liaj ua teb, huab cia network, thiab txhua qhov chaw fiber jumper cables xav tau.

FC-FC 50/125μm OM5 Duplex Fiber Patch Cord

FC UPC-UPC Duplex Fiber Optic Patch Cable, OM5 50/125um Multi-mode, Txiv qaub Green Jacket, 2.0mm, 1M/2M/3M/Custom. FC / UPC duplex optic jumper muaj ob lub fibers thiab ob lub FC txuas ntawm txhua qhov kawg. Nws txoj kev sib txuas yog tiv taus rub, lim thiab cuam tshuam thaum lub sijhawm teeb tsa.

Multimode thaj qaum cables siv 62.5/125 micron los yog 50/125 micron bulk multimode fiber cable nrog multimode fiber optic connectors ntawm ob qho tag nrho thiab txawv cable tsho xim. Rau OM5 fiber ntau patch cords, cov tub ntxhais txoj kab uas hla yog 50µm thiab cov xim ntawm lub tsho fiber ntau yog txiv qaub ntsuab. OM5 fiber ntau kuj hu ua WBMMF (wideband multi-mode fiber). Raws li hom tshiab tshaj plaws ntawm ntau hom fiber ntau, OM5 fiber ntau tau tshaj thiab sib cuam tshuam nrog OM3 thiab OM4 cabling. Nws yog tsim tshwj xeeb los txhawb kev sib faib luv wavelength division multiplexing (SWDM) kis.

Hom ConnectorLC/SC/FC/ST/MU/MTRJ/E2000
Polish HomUPC
Hom FiberMM 50/125um OM5
Ua haujlwm wavelength (nm)850, 1300
Insertion poob (dB)Tsawg dua lossis sib npaug rau 0.25
Rov Los Loss (dB)Ntau dua lossis sib npaug li 35
Rov ua dua (dB)Tsawg dua lossis sib npaug rau 0.10
Interchangeability (dB)Tsawg dua lossis sib npaug rau 0.20
Plug Testing (lub sijhawm)Ntau tshaj los yog sib npaug rau 1000
Tensile zog (N){{0}}.9mm(9N); 2. 0mm(70N); 3.0 hli (75N)
Durability (dB)Tsawg dua lossis sib npaug rau 0.20
Ua haujlwm kub (degree)-40~+85
Cia kub (degree)-20~+75


Nta


Connector hom: FC, feem ntau yog siv rau datacom, ntsuas khoom, lasers thiab lwm yam.

Insertion poob: Tsawg dua lossis sib npaug rau 0.25dB, qis dua IL tuaj yeem hloov kho

Jacket xim: OM5 official txiv qaub ntsuab, los yog kev cai

Kev sib kis nrug: 550m (10GbE), 150m (40GbE / 100GbE)

Jacket khoom: PVC (OFNR) rau riser daim ntaub ntawv thiab cabling nyob rau hauv ib lub tsev ntawm cov plag tsev, LSZH rau kab rov tav structural cabling cheeb tsam.

Kev Tswjhwm Zoo: OPTICO thaj cords 100% kuaj los ntawm cov cuab yeej siv siab ua ntej xa khoom



Daim ntawv thov


  • Cross-connect patching

  • Kev siv pob txha hauv tsev

  • Termination enclosure rau khoom patching

  • Cov khoom siv rau cov khoom siv patching

data center.jpg

Data Center

FTTH.jpg

FTTH

ethernet.png

Ethernet


Test Report


test report1.jpg

Kev ntsuas kub

test report 2.jpg

Tso pov tseg

test report 3.jpg

Durability xeem

test report 4.jpg

Kub & humidity test


test report 5.jpg

Kev ntsuas kub

test report 6.jpg

Kev xeem poob

test report 7.jpg

Khoov-resistant test

test report 8.jpg

Sine vibration test



Cim npe nrov: fc rau fc om5 duplex thaj qaum, Tuam Tshoj fc rau fc om5 duplex thaj qaum manufacturers, lwm tus neeg, Hoobkas

Koj Tseem Yuav Zoo Li

(0/10)

clearall